Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.411
Filtrar
1.
J Gastrointest Surg ; 28(4): 375-380, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38583886

RESUMO

PURPOSE: This study aimed to investigate the correlation between sarcopenia and adverse events (AEs) of postoperative imatinib therapy through computed tomography (CT) quantitative body composition for intermediate- and high-risk gastrointestinal stromal tumors (GISTs). METHODS: The study retrospectively analyzed the clinical data of 208 patients with intermediate- and high-risk GIST treated surgically and treated with imatinib afterward at the First Affiliated Hospital of Wenzhou Medical University between October 2011 and October 2021. Images of preoperative CT scans within 1 month were used to determine the body composition of the patients. On the basis of the L3 skeletal muscle index, patients were classified into sarcopenia and nonsarcopenia groups. In 2 groups, AEs related to imatinib were analyzed. RESULTS: The proportion of AEs related to imatinib in the sarcopenia group was higher, and this disparity had a significant statistical significance (P = .013). Sarcopenia was significantly associated with hemoglobin reduction compared with nonsarcopenia (P = .015). There was a significant difference between the sarcopenia group and the nonsarcopenia group in the ratio of severe AEs (grades 3-4). Hemoglobin content (odds ratio [OR], 0.981; 95% CI, 0.963-1.000; P = .045), sex (OR, 0.416; 95% CI, 0.192-0.904; P = .027), and sarcopenia (OR, 5.631; 95% CI, 2.262-14.014; P < .001) were the influential factors of imatinib severe AEs in patients with intermediate- and high-risk GIST within 1 year after imatinib treatment. CONCLUSION: Patients with preoperative sarcopenia have a higher incidence and severity of AEs during adjuvant imatinib therapy.


Assuntos
Antineoplásicos , Tumores do Estroma Gastrointestinal , Sarcopenia , Humanos , Mesilato de Imatinib/efeitos adversos , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/cirurgia , Estudos Retrospectivos , Sarcopenia/induzido quimicamente , Sarcopenia/diagnóstico por imagem , Quimioterapia Adjuvante , Hemoglobinas , Tomografia , Antineoplásicos/efeitos adversos
2.
Int Braz J Urol ; 50(3): 250-260, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598828

RESUMO

BACKGROUND: Success rates in endourological procedures, notably percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), have demonstrated suboptimal outcomes, leading to more reinterventions and radiation exposure. Recently, the use of intraoperative computed tomography (ICT) scans has been hypothesized as a promising solution for improving outcomes in endourology procedures. With this considered, we conducted a comprehensive systematic review and meta-analysis encompassing all available studies that evaluate the impact of the use of intraoperative CT scans on surgical outcomes compared to conventional fluoroscopic-guided procedures. METHODS: This systematic review was conducted in accordance with PRISMA guidelines. Multiple databases were systematically searched up to December of 2023. This study aimed to directly compare the use of an ICT scan with the standard non-ICT-guided procedure. The primary endpoint of interest was success rate, and the secondary endpoints were complications and reintervention rates, while radiation exposure was also evaluated. Data extraction and quality assessment were performed following Cochrane recommendations. Data was presented as an Odds ratio with 95%CI across trials and a random-effects model was selected for pooling of data. RESULTS: A comprehensive search yielded 533 studies, resulting in the selection of 3 cohorts including 327 patients (103 ICT vs 224 in non-ICT). Primary outcome was significantly higher in the experimental group versus the control group (84.5% vs 41.4% respectively, 307 patients; 95% CI [3.61, 12.72]; p<0.00001; I2=0). Reintervention rates also decreased from 32.6% in the control to 12.6% in the ICT group (OR 0.34; 95%CI [0.12,0.94]; p =0.04; I2= 48%), whereas complication rates did not exhibit significant differences. Radiation exposure was also significantly reduced in two of the included studies. CONCLUSION: This meta-analysis highlights a favorable outcome with intraoperative CT scan use in PCNL procedures, showing a considerable increase in SFR when compared to standard fluoroscopy and nephroscopy. Despite limited studies, our synthesis underscores the potential of ICT scans to significantly reduce residual stones and their consequences for endourology patients, as reinterventions and follow-up ionizing radiation studies.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Cálculos Renais/etiologia , Nefrolitotomia Percutânea/métodos , Rim , Ureteroscopia/métodos , Tomografia , Resultado do Tratamento
3.
Gen Dent ; 72(3): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640006

RESUMO

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Assuntos
Densidade Óssea , Fraturas Mandibulares , Humanos , Estudos Retrospectivos , Densidade Óssea/fisiologia , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Tomografia
4.
BMC Complement Med Ther ; 24(1): 143, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575891

RESUMO

BACKGROUND: This study aimed to determine the therapeutic efficacy of curcumin nanoemulsion (CUR-NE) in mice infected with Echinococcus granulosus sensu stricto protoscoleces. METHODS: Forty-two inbred BALB/c mice were divided into seven groups of six animals each. Six groups were inoculated intra-peritoneally with 1500 viable E. granulosus protoscoleces, followed for six months and used as infected groups. The infected groups were named as: CEI1 to CEI6 accordingly. The 7th group was not inoculated and was named cystic echinococcosis noninfected group (CENI7). CEI1 and CEI2 groups received 40 mg/kg/day and 20 mg/kg/day curcumin nanoemulsion (CUR-NE), respectively. CEI3 received nanoemulsion without curcumin (NE-no CUR), CEI4 received curcumin suspension (CUR-S) 40 mg/kg/day, CEI5 received albendazole 150 mg/kg/day and CEI6 received sterile phosphate-buffered saline (PBS). CENI7 group received CUR-NE 40 mg/kg/day. Drugs administration was started after six months post-inoculations of protoscoleces and continued for 60 days in all groups. The secondary CE cyst area was evaluated by computed tomography (CT) scan for each mouse before treatment and on the days 30 and 60 post-treatment. The CT scan measurement results were compared before and after treatment. After the euthanasia of the mice on the 60th day, the cyst area was also measured after autopsy and, the histopathological changes of the secondary cysts for each group were observed. The therapeutic efficacy of CUR-NE in infected groups was evaluated by two methods: CT scan and autopsied cyst measurements. RESULTS: Septal calcification in three groups of infected mice (CEI1, CEI2, and CEI4) was revealed by CT scan. The therapeutic efficacy of CUR-NE 40 mg/kg/day (CEI1 group) was 24.6 ± 26.89% by CT scan measurement and 55.16 ± 32.37% by autopsied cysts measurements. The extensive destructive effects of CUR-NE 40 mg/kg/day (CEI1 group) on the wall layers of secondary CE cysts were confirmed by histopathology. CONCLUSION: The current study demonstrated a significant therapeutic effect of CUR-NE (40 mg/kg/day) on secondary CE cysts in BALB/c mice. An apparent septal calcification of several cysts revealed by CT scan and the destructive effect on CE cysts observed in histopathology are two critical key factors that suggest curcumin nanoemulsion could be a potential treatment for cystic echinococcosis.


Assuntos
Curcumina , Cistos , Equinococose , Animais , Camundongos , Curcumina/farmacologia , Curcumina/uso terapêutico , Camundongos Endogâmicos BALB C , Equinococose/diagnóstico por imagem , Equinococose/tratamento farmacológico , Tomografia
5.
Crit Care ; 28(1): 124, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627745

RESUMO

Extracorporeal Carbon Dioxide Removal (ECCO2R) is used in acute respiratory distress syndrome (ARDS) patients to facilitate lung-protective ventilatory strategies. Electrical Impedance Tomography (EIT) allows individual, non-invasive, real-time, bedside, radiation-free imaging of the lungs, providing global and regional dynamic lung analyses. To provide new insights for future ECCO2R research in ARDS, we propose a potential application of EIT to personalize End-Expiratory Pressure (PEEP) following each reduction in tidal volume (VT), as demonstrated in an illustrative case. A 72-year-old male with COVID-19 was admitted to the ICU for moderate ARDS. Monitoring with EIT was started to determine the optimal PEEP value (PEEPEIT), defined as the intersection of the collapse and overdistention curves, after each reduction in VT during ECCO2R. The identified PEEPEIT values were notably low (< 10 cmH2O). The decrease in VT associated with PEEPEIT levels resulted in improved lung compliance, reduced driving pressure and a more uniform ventilation pattern. Despite current Randomized Controlled Trials showing that ultra-protective ventilation with ECCO2R does not improve survival, the applicability of universal ultra-protective ventilation settings for all patients remains a subject of debate. Inappropriately set PEEP levels can lead to alveolar collapse or overdistension, potentially negating the benefits of VT reduction. EIT facilitates real-time monitoring of derecruitment associated with VT reduction, guiding physicians in determining the optimal PEEP value after each decrease in tidal volume. This original description of using EIT under ECCO2R to adjust PEEP at a level compromising between recruitability and overdistention could be a crucial element for future research on ECCO2R.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Masculino , Humanos , Idoso , Impedância Elétrica , Respiração com Pressão Positiva/métodos , Pulmão , Tomografia Computadorizada por Raios X , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar , Tomografia/métodos
6.
Physiol Meas ; 45(4)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38565126

RESUMO

Objective.The objective of this study was to propose a novel data-driven method for solving ill-posed inverse problems, particularly in certain conditions such as time-difference electrical impedance tomography for detecting the location and size of bubbles inside a pipe.Approach.We introduced a new layer architecture composed of three paths: spatial, spectral, and truncated spectral paths. The spatial path processes information locally, whereas the spectral and truncated spectral paths provide the network with a global receptive field. This unique architecture helps eliminate the ill-posedness and nonlinearity inherent in the inverse problem. The three paths were designed to be interconnected, allowing for an exchange of information on different receptive fields with varied learning abilities. Our network has a bottleneck architecture that enables it to recover signal information from noisy redundant measurements. We named our proposed model truncated spatial-spectral convolutional neural network (TSS-ConvNet).Main results.Our model demonstrated superior accuracy with relatively high resolution on both simulation and experimental data. This indicates that our approach offers significant potential for addressing ill-posed inverse problems in complex conditions effectively and accurately.Significance.The TSS-ConvNet overcomes the receptive field limitation found in most existing models that only utilize local information in Euclidean space. We trained the network on a large dataset covering various configurations with random parameters to ensure generalization over the training samples.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Tomografia/métodos , Impedância Elétrica , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos
7.
World J Urol ; 42(1): 238, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627315

RESUMO

BACKGROUND: Accurate estimation of the glomerular filtration rate (GFR) is clinically crucial for determining the status of obstruction, developing treatment strategies, and predicting prognosis in obstructive nephropathy (ON). We aimed to develop a deep learning-based system, named UroAngel, for non-invasive and convenient prediction of single-kidney function level. METHODS: We retrospectively collected computed tomography urography (CTU) images and emission computed tomography diagnostic reports of 520 ON patients. A 3D U-Net model was used to segment the renal parenchyma, and a logistic regression multi-classification model was used to predict renal function level. We compared the predictive performance of UroAngel with the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, and two expert radiologists in an additional 40 ON patients to validate clinical effectiveness. RESULTS: UroAngel based on 3D U-Net convolutional neural network could segment the renal cortex accurately, with a Dice similarity coefficient of 0.861. Using the segmented renal cortex to predict renal function stage had high performance with an accuracy of 0.918, outperforming MDRD and CKD-EPI and two radiologists. CONCLUSIONS: We proposed an automated 3D U-Net-based analysis system for direct prediction of single-kidney function stage from CTU images. UroAngel could accurately predict single-kidney function in ON patients, providing a novel, reliable, convenient, and non-invasive method.


Assuntos
Aprendizado Profundo , Insuficiência Renal Crônica , Rim Único , Humanos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico , Taxa de Filtração Glomerular , Tomografia , Creatinina
8.
Eur Respir J ; 63(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38636970

RESUMO

BACKGROUND: Up to 50% of those attending for low-dose computed tomography screening for lung cancer continue to smoke and co-delivery of smoking cessation services alongside screening may maximise clinical benefit. Here we present data from an opt-out co-located smoking cessation service delivered alongside the Yorkshire Lung Screening Trial (YLST). METHODS: Eligible YLST participants were offered an immediate consultation with a smoking cessation practitioner (SCP) at their screening visit with ongoing smoking cessation support over subsequent weeks. RESULTS: Of 2150 eligible participants, 1905 (89%) accepted the offer of an SCP consultation during their initial visit, with 1609 (75%) receiving ongoing smoking cessation support over subsequent weeks. Uptake of ongoing support was not associated with age, ethnicity, deprivation or educational level in multivariable analyses, although men were less likely to engage (adjusted OR (ORadj) 0.71, 95% CI 0.56-0.89). Uptake was higher in those with higher nicotine dependency, motivation to stop smoking and self-efficacy for quitting. Overall, 323 participants self-reported quitting at 4 weeks (15.0% of the eligible population); 266 were validated by exhaled carbon monoxide (12.4%). Multivariable analyses of eligible smokers suggested 4-week quitting was more likely in men (ORadj 1.43, 95% CI 1.11-1.84), those with higher motivation to quit and previous quit attempts, while those with a stronger smoking habit in terms of cigarettes per day were less likely to quit. CONCLUSIONS: There was high uptake for co-located opt-out smoking cessation support across a wide range of participant demographics. Protected funding for integrated smoking cessation services should be considered to maximise programme equity and benefit.


Assuntos
Abandono do Hábito de Fumar , Tabagismo , Masculino , Humanos , Abandono do Hábito de Fumar/métodos , Serviços de Saúde Comunitária , Pulmão , Tomografia
9.
Physiol Meas ; 45(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38624240

RESUMO

Objective.Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the periphery of a heterogeneous conductor are inverted to map its internal conductivity. The EIT method proposed here aims to improve computational speed and noise tolerance by introducing sensitivity volume as a figure-of-merit for comparing EIT measurement protocols.Approach.Each measurement is shown to correspond to a sensitivity vector in model space, such that the set of measurements, in turn, corresponds to a set of vectors that subtend a sensitivity volume in model space. A maximal sensitivity volume identifies the measurement protocol with the greatest sensitivity and greatest mutual orthogonality. A distinguishability criterion is generalized to quantify the increased noise tolerance of high sensitivity measurements.Main result.The sensitivity volume method allows the model space dimension to be minimized to match that of the data space, and the data importance to be increased within an expanded space of measurements defined by an increased number of contacts.Significance.The reduction in model space dimension is shown to increasecomputational efficiency, accelerating tomographic inversion by several orders of magnitude, while the enhanced sensitivitytolerates higher noiselevels up to several orders of magnitude larger than standard methods.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Impedância Elétrica , Tomografia/métodos , Condutividade Elétrica
10.
Urolithiasis ; 52(1): 65, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630281

RESUMO

Extracorporeal shock wave lithotripsy (ESWL) is a safe and efficient treatment option for urinary stone disease. The overall stone-free rate (SFR) varies significantly. This study aimed to assess the influence of stone size, location, stone density, and skin-to-stone distance (SSD), on the outcome of ESWL. We assessed whether pre-treatment non-contrast-enhanced CT scan (NCCT) confers significant advantages compared to kidney-ureter-bladder film (KUB) only. We reviewed the medical records of 307 cases (165 men, 142 women) with renal and ureteral stones treated consecutively at our institution with ESWL between 2020 and 2023. 44 of these underwent a NCCT. The outcome of ESWL was defined in two ways: visible stone fragmentation on KUB, and the need for further treatment. Overall success of fragmentation was 85% (261 patients). 61% of patients (n = 184) didn't need any further treatment. Stone size and location correlated significantly with treatment outcomes regarding the need for further treatment (p = 0.004) and stone fragmentation (p = 0.016), respectively. Unlike mean SSD (p = 0.462), the mean attenuation value (MAV) significantly correlated with the need for retreatment (p = 0.016). MAV seems to be a better predictor of treatment success (AUC of the ROC curve: 0.729), compared to stone size (AUC: 0.613). The difference between groups (with and without NCCT) in both treatment outcomes did not reach statistical significance. During decision-making, information regarding SSD and MAV can be useful in more dubious scenarios. However, it appears that their inclusion doesn't provide substantial advantages when compared to relying solely on KUB.


Assuntos
Litotripsia , Cálculos Ureterais , Masculino , Humanos , Feminino , Estudos Retrospectivos , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/terapia , Rim , Computadores , Tomografia
11.
Zhonghua Yi Xue Za Zhi ; 104(15): 1247-1252, 2024 Apr 16.
Artigo em Chinês | MEDLINE | ID: mdl-38637164

RESUMO

Acute respiratory distress syndrome (ARDS) is a common and critical clinical condition characterized by diffuse damage to the lung interstitium, alveoli, and increased permeability of pulmonary blood vessels. CT can be used to assess the imaging features, severity, and prediction of ARDS, but it requires patient transportation to the CT room and is only a static examination. Electrical impedance tomography (EIT) is an increasingly widely used monitoring tool in clinical applications in recent years. It enables continuous real-time assessment of lung ventilation distribution at the bedside and has high clinical value in optimizing mechanical ventilation parameters for critically ill patients. This article introduces the basic principles of EIT and how to better utilize EIT technology to guide mechanical ventilation treatment for ARDS patients.


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/métodos , Impedância Elétrica , Tomografia/métodos , Síndrome do Desconforto Respiratório/terapia , Tomografia Computadorizada por Raios X/métodos , Pulmão
12.
Rev. esp. anestesiol. reanim ; 71(4): 291-297, abril 2024. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-232124

RESUMO

Antecedentes: Los bloqueos continuos de los nervios periféricos son de uso común para el manejo del dolor. Sin embargo, la incidencia de desplazamiento o migración del catéter es dudosa, pudiendo ser infraestimada y no denunciarse. Nuestro objetivo fue evaluar el posicionamiento del extremo del catéter supraescapular antes y después de la manipulación rutinaria y simulada mediante fisioterapia de hombro en un modelo cadavérico anatómico.MétodoSe colocaron 8 catéteres para bloqueo continuo y ecoguiado del nervio supraescapular en cadáveres frescos criopreservados. La tomografía computarizada (TC) confirmó la localización de la punta del catéter tras la inyección de 1ml de medio de contraste. Realizamos una serie de movimientos estandarizados de hombro durante una sesión simulada de fisioterapia de hombro en cadáveres. Tras ello, administramos 1ml de azul de metileno a través de los catéteres, y seguidamente realizamos disecciones para identificar con precisión la localización de las puntas del catéter y compararlas con su localización previa a la «fisioterapia».ResultadosLa imagen de la TC confirmó la localización en todos los casos de los extremos del catéter en la muesca supraescapular. Sin embargo, tras la fisioterapia, se encontró que 2 catéteres (25%) habían migrado y, en especial, uno fue localizado en el músculo supraespinoso y el otro en el músculo trapecio.ConclusiónNuestros hallazgos sugieren que el desplazamiento del catéter puede producirse en cerca del 25% de los casos tras la manipulación mediante fisioterapia simulada. Sin embargo, es necesaria más investigación para determinar la incidencia real de los desplazamientos del catéter en la práctica clínica. (AU)


Background: Continuous peripheral nerve blocks are commonly used for pain management. However, the incidence of catheter dislodgement or migration is unclear, and may be underestimated and underreported. Our objective was to assess suprascapular catheter tip positioning before and after routine simulated shoulder physiotherapy manipulation in an anatomical cadaver model.MethodEight ultrasound-guided continuous suprascapular nerve block catheters were placed in cryopreserved fresh cadavers. Computed tomography (CT) confirmed the location of the catheter tip after injection of 1ml of contrast medium. We performed a series of standardized shoulder movements during a simulated shoulder physiotherapy session in cadavers. Following this, we administered 1ml of methylene blue through the catheters, and then performed anatomical dissections to accurately identify the location of the catheter tips and compare them to their placement prior to the ‘physiotherapy’ResultCT imaging confirmed the location of the catheter tips at the suprascapular notch in all cases. However, following physiotherapy, 2 catheters (25%) were found to have migrated - specifically, 1 was located in the supraspinatus muscle, and the other was located in the trapezius muscle.ConclusionOur findings suggest that catheter dislodgement may occur in approximately 25% of cases following simulated physiotherapy manipulation. However, further research is needed to determine the read incidence of catheter dislodgement in clinical practice. (AU)


Assuntos
Humanos , Tomografia , Modalidades de Fisioterapia , Anatomia , Anestesia por Condução
13.
Arch. Soc. Esp. Oftalmol ; 99(4): 165-168, abr. 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-232137

RESUMO

La cavitación intracoroidea es un hallazgo identificado con OCT descrito inicialmente en pacientes miopes, pero también aparece en pacientes no miopes. Puede presentarse tanto en el área peripapilar como en el polo posterior. El coloboma macular es un defecto del desarrollo embrionario del polo posterior, y en la OCT estructural es imprescindible la ausencia del epitelio pigmentario de la retina y de los vasos coroideos para su diagnóstico. Este caso presenta la cavitación intracoroidea circunscribiendo el coloboma macular, en ausencia de membrana intercalar. La imagen en face permite valorar la relación entre ambas estructuras, así como la magnitud de las mismas. (AU)


Intrachoroidal cavitation is a finding identified with OCT initially described in myopic patients, it also appears in non-myopic patients. It can occur in both the peripapillary area and the posterior pole. Macular coloboma is a defect of embryonic development of the posterior pole, in structural OCT the absence of the retinal pigment epithelium and choroidal vessels is essential. In this case, intrachoroidal cavitation circumscribes the macular coloboma, in the absence of an intercalary membrane. The face image allows us to assess the relationship between the two structures as well as their magnitude. (AU)


Assuntos
Humanos , Coloboma , Tomografia , Miopia Degenerativa , Cavitação , Oftalmologia
14.
Respir Res ; 25(1): 135, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509592

RESUMO

INTRODUCTION: Computed tomography (CT) is routinely employed on the evaluation of dyspnea, yet limited data exist on its assessment of diaphragmatic muscle. This study aimed to determine the capability of CT in identifying structural changes in the diaphragm among patients with ultrasound-confirmed diaphragmatic dysfunction. METHODS: Diaphragmatic ultrasounds conducted between 2018 and 2021 at our center in Marseille, France, were retrospectively collected. Diaphragmatic pillars were measured on CT scans at the L1 level and the celiac artery. Additionally, the difference in height between the two diaphragmatic domes in both diaphragmatic dysfunction cases and controls was measured and compared. RESULTS: A total of 65 patients were included, comprising 24 with diaphragmatic paralysis, 13 with diaphragmatic weakness, and 28 controls. In the case group (paralysis and weakness) with left dysfunctions (n = 24), the CT thickness of the pillars at the level of L1 and the celiac artery was significantly thinner compared with controls (2.0 mm vs. 7.4 mm and 1.8 mm vs. 3.1 mm, p < 0.001 respectively). Significantly different values were observed for paralysis (but not weakness) in the right dysfunction subgroup (n = 15) (2.6 mm vs. 7.4 mm and 2.2 mm vs. 3.8 mm, p < 0.001 respectively, for paralysis vs. controls). Regardless of the side of dysfunction, a significant difference in diaphragmatic height was observed between cases and controls (7.70 cm vs. 1.16 cm and 5.51 cm vs. 1.16 cm, p < 0.001 for right and left dysfunctions, respectively). Threshold values determined through ROC curve analyses for height differences between the two diaphragmatic domes, indicative of paralysis or weakness in the right dysfunctions, were 4.44 cm and 3.51 cm, respectively. Similarly for left dysfunctions, the thresholds were 2.70 cm and 2.48 cm, respectively, demonstrating good performance (aera under the curve of 1.00, 1.00, 0.98, and 0.79, respectively). CONCLUSION: In cases of left diaphragmatic dysfunction, as well as in paralysis associated with right diaphragmatic dysfunction, CT revealed thinner pillars. Additionally, a notable increase in the difference in diaphragmatic height demonstrated a strong potential to identify diaphragmatic dysfunction, with specific threshold values.


Assuntos
Diafragma , Debilidade Muscular , Humanos , Diafragma/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia/métodos , Paralisia , Tomografia Computadorizada por Raios X , Tomografia
15.
Syst Rev ; 13(1): 88, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493159

RESUMO

PURPOSE: Lung cancer is the leading cause of cancer deaths in Canada, and because early cancers are often asymptomatic screening aims to prevent mortality by detecting cancer earlier when treatment is more likely to be curative. These reviews will inform updated recommendations by the Canadian Task Force on Preventive Health Care on screening for lung cancer. METHODS: We will update the review on the benefits and harms of screening with CT conducted for the task force in 2015 and perform de novo reviews on the comparative effects between (i) trial-based selection criteria and use of risk prediction models and (ii) trial-based nodule classification and different nodule classification systems and on patients' values and preferences. We will search Medline, Embase, and Cochrane Central (for questions on benefits and harms from 2015; comparative effects from 2012) and Medline, Scopus, and EconLit (for values and preferences from 2012) via peer-reviewed search strategies, clinical trial registries, and the reference lists of included studies and reviews. Two reviewers will screen all citations (including those in the previous review) and base inclusion decisions on consensus or arbitration by another reviewer. For benefits (i.e., all-cause and cancer-specific mortality and health-related quality of life) and harms (i.e., overdiagnosis, false positives, incidental findings, psychosocial harms from screening, and major complications and mortality from invasive procedures as a result of screening), we will include studies of adults in whom lung cancer is not suspected. We will include randomized controlled trials comparing CT screening with no screening or alternative screening modalities (e.g., chest radiography) or strategies (e.g., CT using different screening intervals, classification systems, and/or patient selection via risk models or biomarkers); non-randomized studies, including modeling studies, will be included for the comparative effects between trial-based and other selection criteria or nodule classification methods. For harms (except overdiagnosis) we will also include non-randomized and uncontrolled studies. For values and preferences, the study design may be any quantitative design that either directly or indirectly measures outcome preferences on outcomes pertaining to lung cancer screening. We will only include studies conducted in Very High Human Development Countries and having full texts in English or French. Data will be extracted by one reviewer with verification by another, with the exception of result data on mortality and cancer incidence (for calculating overdiagnosis) where duplicate extraction will occur. If two or more studies report on the same comparison and it is deemed suitable, we will pool continuous data using a mean difference or standardized mean difference, as applicable, and binary data using relative risks and a DerSimonian and Laird model unless events are rare (< 1%) where we will pool odds ratios using Peto's method or (if zero events) the reciprocal of the opposite treatment arm size correction. For pooling proportions, we will apply suitable transformation (logit or arcsine) depending on the proportions of events. If meta-analysis is not undertaken we will synthesize the data descriptively, considering clinical and methodological differences. For each outcome, two reviewers will independently assess within- and across-study risk of bias and rate the certainty of the evidence using GRADE (Grading of Recommendations Assessment, Development, and Evaluation), and reach consensus. DISCUSSION: Since 2015, additional trials and longer follow-ups or additional data (e.g., harms, specific patient populations) from previously published trials have been published that will improve our understanding of the benefits and harms of screening. The systematic review of values and preferences will allow fulsome insights that will inform the balance of benefits and harms. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42022378858.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Adulto , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Qualidade de Vida , Canadá , Revisões Sistemáticas como Assunto , Tomografia Computadorizada por Raios X , Serviços Preventivos de Saúde , Tomografia , Metanálise como Assunto
16.
J Vis Exp ; (205)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38497624

RESUMO

Most infections take place within three-dimensional host tissues with intricate anatomy and locally varying host physiology. The positioning of pathogen cells within this diverse environment significantly affects their stress levels, responses, fate, and contribution to the overall progression of the disease and treatment failure. However, due to the technical difficulties in locating µm-sized pathogen cells within cm-sized host organs, this area of research has been relatively unexplored. Here, we present a method for addressing this challenge. We employ serial two-photon tomography and AI-enhanced image analysis to locate individual Salmonella cells throughout the entire spleen, liver lobes, and whole lymph nodes of infected mice. Using fluorescent reporters and in vivo antibody administration, the replication rate of single Salmonella cells, their local interaction with specific immune cells, and bacterial responses to antibiotics can be determined. These methodologies open avenues for a comprehensive examination of infections, their prevention, and treatment within the three-dimensional tissue context.


Assuntos
Antibacterianos , Salmonella , Animais , Camundongos , Baço/diagnóstico por imagem , Linfonodos , Tomografia
17.
Anticancer Res ; 44(4): 1583-1589, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38537975

RESUMO

BACKGROUND/AIM: Concurrent cisplatin-based chemoradiotherapy (CCRT) is the standard treatment for locally advanced cervical cancer. Especially, CCRT with magnetic resonance imaging (MRI) or computed tomography-based image-guided brachytherapy (CT-based 3D-IGBT) for cervical cancer has resulted in good LC rates. However, progression-free survival (PFS) and overall survival (OS) rates for locally advanced cervical cancer are still low and could be improved. The aim of the study was to evaluate treatment efficacy and late toxicity of external beam radiotherapy (EBRT) and CT-based IGBT with or without concurrent chemotherapy in patients with squamous cell carcinoma of the uterine cervix and investigate patterns of failure. PATIENTS AND METHODS: We retrospectively analyzed clinical data of cervical squamous cell carcinoma patients treated with definitive radiotherapy with or without concurrent chemotherapy at Saitama Medical University International Medical Center. Local control (LC), PFS, patterns of failure, and late toxicity were the evaluated outcomes. RESULTS: Overall, 290 patients were enrolled in the study. Median follow-up was 51.5 months. During follow-up, 74 patients developed recurrence: 10 patients with intra-pelvic failure only, 45 with extra-pelvic failure only, and 19 with both. The 3-year LC was 100% for T1b-T2a, 96.8% for T2b, 89.5% for T3b, and 88.5% for T4 disease. The 3-year PFS was 100% for stage IB-IIA, 89.0% for stage IIB, 70.7% for stage IIIB, 72.6% for stage IIIC1r, and 40.1% for stage IVA. The incidence of grade 3-4 gastrointestinal and genitourinary toxicities was 3.0% and 1.7%, respectively. CONCLUSION: Combination of EBRT and CT-based IGBT with or without concurrent chemotherapy produced favorable LC with acceptable rates of late toxicities. However, extra-pelvic failures frequently occurred and PFS was less satisfactory in patients with stage III-IVA disease, which indicated the need for additional treatment in these patients.


Assuntos
Braquiterapia , Carcinoma de Células Escamosas , Neoplasias do Colo do Útero , Feminino , Humanos , Carcinoma de Células Escamosas/terapia , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/métodos , Estudos Retrospectivos , Cisplatino/uso terapêutico , Resultado do Tratamento , Quimiorradioterapia/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Tomografia , Estadiamento de Neoplasias
19.
BMC Ophthalmol ; 24(1): 138, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38539111

RESUMO

PURPOSE: To assess the level of agreement and evaluate the reliability of measurements between two Scheimpflug imaging modalities, Scansys (MediWorks, China) and Sirius (CSO, Italy), in quantifying the anterior segment parameters in healthy eyes. METHODS: In a cross-sectional study, the right eyes of 38 healthy participants without any ocular or systemic diseases were examined. A range of anterior segment parameters including anterior and posterior flat and steep keratometry, central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), anterior chamber angle (ACA), corneal volume, anterior chamber volume, and horizontal white to white diameter, derived from the sagittal curvature maps were measured. To evaluate the reliability of the measurements, intraclass correlation coefficient (ICC) and correlation coefficient were measured. Additionally, Bland-Altman plots were employed to examine the agreement in mean (bias line) and 95% limits of agreement between the two devices. RESULTS: The mean age was 31.5 ± 6.9 (range: 19-47) years. The ICC indicated that the majority of anterior segment parameters had an excellent or good level of reliability, surpassing the threshold of 0.9. Nevertheless, CCT and ACA exhibited a moderate level of reliability, with ICC values of 0.794 and 0.728, respectively. The correlation analysis showed a strong correlation for all the variables tested. The Bland-Altman plots revealed that the bias line was near zero and the 95% limits of agreement were narrow for most variables, except for the anterior flat and steep keratometry, which were found to range from - 0.57 to 0.84 D and - 0.68 to 0.87 D, respectively. CONCLUSION: Scansys and Sirius devices can be effectively used interchangeably for the evaluation of most anterior segment parameters; however, for anterior corneal curvatures, CCT and ACA, their alternative use is not recommended.


Assuntos
Córnea , Tomografia , Humanos , Adulto Jovem , Adulto , Reprodutibilidade dos Testes , Estudos Transversais , Estudos Prospectivos , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Tomografia de Coerência Óptica
20.
Radiol Clin North Am ; 62(3): 399-417, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553177

RESUMO

Valvular heart disease (VHD) is a significant clinical problem associated with high morbidity and mortality. Although not being the primary imaging modality in VHD, cardiac computed tomography (CCT) provides relevant information about its morphology, function, severity grading, and adverse cardiac remodeling assessment. Aortic valve calcification quantification is necessary for grading severity in cases of low-flow/low-gradient aortic stenosis. Moreover, CCT details significant information necessary for adequate percutaneous treatment planning. CCT may help to detail the etiology of VHD as well as to depict other less frequent causes of valvular disease, such as infective endocarditis, valvular neoplasms, or other cardiac pseudomasses.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Humanos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Valva Aórtica , Radiografia , Tomografia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...